Peacefair PZEM-004T AC Multi-function Energy Meter Module — A high-precision single-phase power monitor measuring AC voltage (80–260V), current (10A/100A), active power (up to 23kW), frequency, power factor, and active energy (0–9999.99 kWh) with ±0.5% accuracy. Features TTL UART Modbus-RTU communication, software-resettable energy counter, over-power alarm, and non-invasive CT current sensing. Ideal for Arduino, ESP32, Raspberry Pi, IoT smart meters, and industrial load monitoring applications.
₹995.00 (Excl GST)
| Quantity | Discount | Discounted price |
| 10 - 29 | 2.5% | ₹970.13 |
| 30 - 69 | 5% | ₹945.25 |
| 70 - 100 | 7.5% | ₹920.38 |
The Peacefair PZEM-004T is a high-precision single-phase AC multi-function energy metering module designed for measuring AC voltage, current, active power, frequency, power factor, and active energy in real-time. Available in 10A (built-in shunt) and 100A (external CT) variants, this compact module communicates via a TTL UART serial interface using the Modbus-RTU protocol, making it ideal for integration with Arduino, ESP32, Raspberry Pi, and other microcontroller platforms. With 0.5% measurement accuracy, software-resettable energy accumulation, and an over-power alarm function, it is the go-to solution for IoT-based smart energy meters, home automation, industrial load monitoring, and power analysis applications.
| Parameter | Specification |
|---|---|
| Model | PZEM-004T V3.0 / V4.0 |
| Measurement Type | Single-Phase AC Multi-function Energy Meter |
| Voltage Measurement Range | 80V – 260V AC |
| Voltage Resolution | 0.1V |
| Voltage Accuracy | ±0.5% |
| Current Measurement Range | 0 – 10A (PZEM-004T-10A) / 0 – 100A (PZEM-004T-100A) |
| Starting Measure Current | 0.01A (10A) / 0.02A (100A) |
| Current Resolution | 0.001A |
| Current Accuracy | ±0.5% |
| Active Power Range | 0 – 2.3kW (10A) / 0 – 23kW (100A) |
| Starting Measure Power | 0.4W |
| Power Resolution | 0.1W |
| Power Accuracy | ±0.5% |
| Frequency Range | 45Hz – 65Hz |
| Frequency Resolution | 0.1Hz |
| Frequency Accuracy | ±0.5% |
| Power Factor Range | 0.00 – 1.00 |
| Power Factor Resolution | 0.01 |
| Power Factor Accuracy | ±1% |
| Active Energy Range | 0 – 9999.99 kWh |
| Energy Resolution | 1 Wh |
| Energy Accuracy | ±0.5% |
| Energy Reset | Software reset via Modbus command |
| Over Power Alarm | Programmable threshold, alarm when exceeded |
| Communication Interface | TTL UART (passive, requires external 5V) |
| Communication Protocol | Modbus-RTU |
| Baud Rate | 9600 (fixed) |
| Data Format | 8 data bits, 1 stop bit, no parity |
| Slave Address Range | 0x01 – 0xF7 (0x00 = broadcast, 0xF8 = general/calibration) |
| Supply Voltage (Logic) | 5V DC (external, required for TTL communication) |
| Operating Temperature | -20℃ to +60℃ |
| Module Dimensions | ~73.7mm × 30mm × 14.3mm (bare PCB) |
| CT Clamp Inner Diameter | ~33mm (100A split-core CT) |
| Mounting Holes | 3.0mm – 3.2mm (M3 compatible) |
| Application Type | Arduino, ESP32, Raspberry Pi, IoT energy monitoring, smart metering |